OpenFOAM cases

Runnable OpenFOAM cases from Inviscid AI. Each directory under cases/ is one self-contained case with the setup that produced its results, so a claim made anywhere else can be checked here.

case what it is
cases/roomFanInOut2D A fan in a room, blowing in versus blowing out. Two runs differing in one setting. Backs a published clip.
cases/motorcycleWindscreen A windscreen at three heights, and how much the air on the rider's helmet fluctuates. Three runs differing in one thing. Backs a published clip, and its limits say why it names no winner.
cases/airFryerVsOven An air fryer and a convection oven with the same fan and the same food, and where the air goes. Two runs differing in the appliance. Backs a published clip, and its limits say why it names no winner.
cases/portableAcHoses A portable air conditioner with one hose and with two, in the same room. One case, run two ways. Backs a published clip; the README says what the numbers can and cannot carry.
cases/sphericalCow The physics joke taken literally: a cow (Keenan Crane's public-domain Spot) and a sphere of the same volume in the same wind. Floating runs under SST-SAS back a published clip; grounded SST runs and a failed sphere drag check are kept, and the README says what that leaves standing.
cases/ceilingFanWinter A ceiling fan in a heated room, off, blowing down and reversed, from switch-on. An axisymmetric wedge with swirl and a check that the wedge carries the swirl's fictitious forces unaided. Backs a published clip; the README says why the fan-off room is the weakest of the three.
cases/ceilingFanHighCeiling The reversed fan of ceilingFanWinter under a ceiling twice as high, the mesh extended at the same resolution and the heater doubled so each cubic metre gets the same heat; the 1300 W runs are kept. Backs a published clip; the README says why the result belongs to equal heat per volume and not to moving the same heater into a taller room.
cases/marathonDrafting A runner at women's world-record marathon pace alone, behind one pacer and behind two side by side, as static CC0 figures over a moving ground under SST-SAS. Backs a published clip; the README says why it finds less shelter than the literature.
cases/pcCaseAirflow A generic mid-tower PC with its case fans in three layouts (more in than out, more out than in, three and three), the card and CPU cooler as fixed-flow heat sources, from switch-on under SST-SAS. Backs a published clip; the README says why the pressure's sign barely matters here and what does. A fourth layout is a viewer's build from that clip's comments, with two bottom intakes, no front fans and the CPU cooler turned round, on its own mesh. Backs a published clip; the README says why its cooler's near-room air is the optimistic end. A fifth is another viewer's build, two low front intakes with rear and rear top exhausts, on the shared mesh. Backs a published clip; the README says why it gains less than the fourth and cannot be told apart from three and three. The first two layouts again with the room's dust carried on the flow as a passive scalar, the front and top behind filter mesh that catches half of it and the slot covers unfiltered. Backs a published clip; the README says why it shows where dusty air goes and not where dust settles, and why positive pressure does not stop the slot leak. Two more layouts are a third viewer's build, the CPU on an all-in-one liquid cooler with a 360 mm radiator on three top exhausts, three front intakes and the rear exhaust, with and without two bottom intakes, on a mesh of their own. Backs a published clip; the README says why most of the air the bottom intakes add leaves the case where the clip's section cannot show it. The last two answer a comment under the first clip, the same liquid cooler in the PC with three and three's fans and its radiator on the three front intakes or on the two top exhausts, the radiator as the heat it adds to its fans' air, on a mesh of their own. Backs a clip; the README says why each position wins on one part, and why the two runs are two realizations of one flow rather than the same air moving.
cases/radiatorUnderWindow A radiator under a cold window against the same radiator on the opposite wall, a 2-D buoyant room section from switch-on to an hour, the radiator's output set to the section's own heat loss. Backs a published clip; the README says why the output is a tenth of a real radiator's, and that its reason for the floor draught opposite running at half the correlation's beyond 1 m is untested. Two more runs put a floor-length curtain over the radiator under the window, hanging in front of it and tucked in at the sill, as an impermeable sheet that conducts heat, over the first 300 s from switch-on. Backs a clip; the README says why, in a 2-D section with no air round the curtain's ends, no radiation and a 60 W/m plume, the shares of heat reaching the room compare the two shapes and do not measure a real curtain, and why the one laboratory measurement, made with no window, does not check them. A third curtain run hangs the same curtain but ends it at the sill, 0.14 m above the radiator, as German advice says to. Backs a clip; the README says why it gains little over the floor-length curtain, the gap behind it becoming a channel for cold air off the glass, and why the curtain holds the heat back by being airtight, not by insulating.
cases/spinningCat The spinning cat of the "OIIA" meme on a floor in still air, from rest, its zone of the mesh turning with it under SST-SAS; the cat is a remeshed CC BY 4.0 model by Zhuier, credited in the case. Backs a published clip; the README says how the run was restarted and its Courant limit raised, and that the flow has not settled by 10 s.
cases/cyclistBehindLorry A road cyclist at 90 km/h alone, 1.5 m behind a lorry's rear doors and 10 m back, a static MakeHuman CC0 rider on a simplified bike behind a generic box lorry built from published dimensions, from rest under SST-SAS. Backs a published clip; the README says why the close rider is sheltered rather than pulled, and why, on a coarse mesh, the shares of riding alone carry the result and the newtons do not. A fourth run is the same lorry alone in its own frame at 80 km/h, overtaking a rider at 20 km/h with a 1.5 m gap; the rider is a probe read off the solve along his path, and the air's force on him a quasi-steady estimate from published drag areas. Backs a clip; the README says why the rider is not in the solve, why the air pushes him once and pulls him once rather than pulling twice, and why the force is an estimate to read against a 17 N flipping limit, not a measurement. Three more runs put a generic car built from published dimensions behind the same lorry at 90 km/h, alone, tailgating 12.5 m behind its doors and at the two-second gap of 50 m, its drag share turned into fuel saved with the National Research Council's half of a car's fuel going on drag at motorway speed; the lorry's emergency stop that follows is kinematics from sourced reaction and braking figures, not CFD. Backs a clip; the README says why the car's absolute drag is too high but its share is used, and why whether the tailgater hits the lorry turns on the reaction time.
cases/heatPumpCover A heat pump's outdoor unit, built from a Daikin ERGA06EV's published dimensions, switched on in still air at 2 C in the open and inside a louvred cover with a solid lid, a 3-D half model on one snappyHexMesh mesh from the fan's switch-on to 60 s, the coil as a capped cooling of fixed effectiveness and the fan as a fixed flow. Backs a clip; the README says why the run's own coil-inlet monitor reads 0.24 K too cold and how the clip's number corrects it, and why a half model with a fixed fan, no wind and no frost bounds what 0.7 C colder can mean. Three more runs try the fixes viewers offered, with nothing changed but the cover: the same cover rebuilt as the control, its slats turned to rise 35 degrees outward, and its front moved out to 350 mm from the grille with the bottom boards left off, each on its own mesh, the first two to 90 s. Backs a clip; the README says why slats up's number is a range of 0.2 to 0.3 C rather than one settled value, why the moved cover's two changes cannot be told apart, and why a model with no rain or snow cannot weigh what upward slats let in.
cases/lorryClosePass2D A lorry overtaking a cyclist at 1.5 m and at 30 cm, in a 2-D horizontal section at his shoulder height, the rider a drag term moving through the fixed mesh, after a precursor of the lorry alone, under k-omega SST. Backs a clip; the README says why, with no air over the roof and an exaggerated wake behind the doors, it reports the 30 cm pass's push and pull only as multiples of the 1.5 m pass's, why the clip stops 2.5 m past the doors, and how its 1.5 m pass compares with cyclistBehindLorry's 3-D estimate, which carries the newtons.
cases/windowAiring The window above radiatorUnderWindow's radiator opened on a still 0 C morning, turned wide open and on tilt, in that room made 3-D and 3.5 m wide, from the moment it opens to 300 s, the tilted sash a solid profile from published fittings and the room's own air a passive scalar. Backs a clip; the README says why the stratified room makes its 91% replaced read high against a well-mixed decay, why the inflow is the figure to set beside measured air-change rates, and why both runs sit above the one measured bedroom while matching the authorities' ranges and the 10% ratio for a tilted window. Two more runs put a US double-hung window from Andersen's published sizes in the same wall, its top sash lowered 10 cm or the same 10 cm split between the top sash lowered 5 cm and the bottom sash raised 5 cm, on the same still morning with the outdoor air held at its barometric pressure. Backs a clip; the README says how the split, working as a stack, takes in seven times the air through the same open area, more than the textbook formulas' five times, and why wind, which a still morning leaves out, would change both.
cases/fanShaftFall A man falling belly-down from rest 7.62 m down a 3 m square shaft, over a cooling fan blowing 10 m/s up it and in the 49.4 m/s updraft that holds his weight, a static MakeHuman CC0 figure held in his own frame with the air coming at him at the updraft plus his fall speed, from a drag curve solved first, under SST-SAS on one coarse mesh. Backs a clip; the README says why the fan is drawn and not solved, why the drag rests on a check against a skydiver's terminal speed rather than on the mesh, and that in the film magnets stop him, not the air.
cases/dryIceCauldron A Halloween cauldron of dry ice on a coffee table in a living room, the front door shut and open to a still 10 C evening, from the moment the dry ice goes in to 600 s, a 3-D half model with O2, N2 and CO2 as real gases so the CO2 is heavier than air, the source a steady 2.5 g/s from the sellers' own recipes. Backs a clip; the README says why the open door raises the CO2 at a toddler's nose for the first four minutes instead of draining it, why its numbers set beside workplace limits for adults are not a risk to a child, and why an empty room and a source that never slows bound what they mean. A third run stands the same cauldron on a 36 in counter-height table in the shut room, beside the shut run solved again. Backs a clip; the README says why raising it does not keep the gas from the toddler but changes when it arrives, higher at the nose for the first 5 min 48 s and lower after, and why its layer, deeper and weaker, is richer from 0.7 to 1.4 m.
cases/iceDamRoofVents An attic under snow on the US Army cold regions laboratory's still 22 F design night for ice dams, its soffit vents (the vent slots under the roof's overhang) open under a baffle and buried in blown insulation, a 2-D section from gable side to gable side with the roof's layers and the snow as resistances, from rest to an hour and the buried attic on to two, reporting the share of the roof over the attic whose snow melts from below. Backs a clip; the README says why the buried attic's number is its settled value, reached after the hour the clip shows, and why an airtight ceiling, solids that hold no heat and one design night bound what 0% against 44% can mean.
cases/foggyWindscreen A car's misted windscreen cleared by the heater on outside air or on recirculation with the A/C off, on a 3 C, 90% morning with two people inside, a 2-D section lengthwise through a generic hatchback's cabin at the driver's centreline for the ten minutes from the blower starting, the water vapour carried by the flow, a film of water condensing on and evaporating from each glass face, and air above saturation turning to mist; the occupants' water comes from the breath and upper body, the defroster's 100 l/s from a Volvo defrost test. Backs a clip; the README says why the clearing edge is level where a real screen's corners clear last, why the windscreen drawn above each section is a drawing that follows the film rather than solved optics, and why a working A/C could turn 0% against 46% round while a cold engine would delay both.
cases/underfloorVsRadiator windowAiring's room with its window shut on a still 0 C morning, heated with the same 60 W by the radiator under the window or spread over the whole floor, a 3-D room from switch-on to 1200 s with the glass losing heat to 0 C and the other walls and the ceiling held at 20 C, reporting how much warmer the air is at a seated person's head than at the ankles. Backs a clip; the README says why both rooms end about 0.3 C warmer at the head for different reasons, the radiator's warm air under the ceiling and the floor's cool current along it, and why a 60 W load with only the glass losing heat may understate how much a real room with cold outside walls stratifies.
cases/roofWindowAiring An attic room with a 45-degree roof and a 1.0 m knee wall, aired on a still 0 C morning through a VELUX GGL PK08 centre-pivot roof window turned wide open, its sash turned top edge into the room as VELUX draws it so that it lies across the opening like a shelf, against windowAiring's room and wall window wide open, rebuilt with the outdoor air at its barometric pressure, from the moment they open to 300 s, the room's own air a passive scalar. Backs a clip; the README says why the roof window takes in about two thirds of the wall window's air, close to what its shorter height gives in the single-opening formula, how the first build turned the sash the wrong way, and why wind, which a still morning leaves out, would change both rooms' numbers.
cases/airingRadiatorValve windowAiring's room aired on a still 0 C morning, its window wide open for five minutes and then shut for ten, once with the radiator's thermostatic valve turned off while the window is open and once left on: a Stelrad K1 sized for the room's 546 W design loss behind a Danfoss RA 2000 valve with its head's 10-minute lag and the radiator's stored heat, every room surface a 1-D layer that stores heat, the window wall conducting through its 24 cm to the outdoor air, EN 12831's 0.5 air changes an hour of leaks and EN ISO 6946's radiation onto the window wall, in a compiled library, from the moment the window opens to 900 s. Backs a clip; the README says why leaving the valve on costs only about 1% more heat over the 15 minutes, 353 against 348 Wh, the shut radiator's body going on heating the room, and why one room, one airing on a still day and one valve bound that figure.
cases/radiatorCover radiatorUnderWindow's room section with its radiator, a Stelrad K1, held at 55 C instead of giving 60 W/m, its convector's one resistance fitted to the catalogue rating, switched on bare and inside a B&Q horizontal-grill MDF cover with a solid top, with radiation, on a finer mesh of its own, from switch-on to 300 s. Backs a clip; the README says why the heat crossing the cover, 69.9% of the bare radiator's over the five minutes, moves from 65% to 75% minute by minute as the bare room warms faster, and why a 2-D section, a cover with no heat capacity, an adiabatic wall behind it and a room with almost no losses make it a comparison of two shapes rather than a real cover's cost. A third run stands an IKEA BACKSAELEN 3-seat sofa 15 cm in front of the bare radiator, cut out of the same mesh and refined along it, its surface a thin layer of fabric over foam that stores heat. Backs a clip; the README says why the radiator gives 92% of its bare output and yet the room's air ends slightly warmer, 27.9 against 27.5 C at five minutes, because the ceiling and inner wall held at 20 C absorb 37 kJ/m of the bare panel's radiation against 10 kJ/m behind the sofa, and why that makes it no finding that a sofa helps a radiator. A further pair gives the radiator a convector with the resistance of a published 6.31 mm fin gap, not Stelrad's, and fins that heat its air through a conductance fitted to the catalogue rating, and runs it bare and with two SpeedComfort Duo fans under it as a forced-air zone at about their rated 2 x 30 m3/h. The README says why the fans give 106.45% of the bare radiator's heat over the five minutes, all of it convection, with the room 0.78 K warmer: only a quarter to a third of the fans' extra air enters the fins, a third of the output is radiation, and the fitted fin conductance, about a tenth of a physical fin's, probably understates the gain.
cases/showerFanVsWindow A 2.5 x 2.0 m bathroom with its door shut on a still 0 C morning, after a ten-minute shower that puts 0.17 kg of water vapour and 300 W into the air, cleared for fifteen minutes by a ceiling extractor at Approved Document F's 15 l/s with the window shut, or by windowAiring's sash on tilt with the fan off, in one solved shower and two branches with O2, N2 and water vapour as real gases and a tracer of the outdoor air in the window run. Backs a clip; the README says why the window takes out 86% of the vapour against the fan's 76% with about as much air, why the door's undercut helps it, why the humidity on the section needs the tracer and an assumed background, and why, with no condensation, walls held at 20 C and a still morning, the vapour removed is not the water. A third branch runs the fan and the tilted window together after the same shower, from the window run's state with the grille opened, at Courant 2 after a Courant 1 check that agrees to about 1%. Backs a clip; the README says why the two together take out 91% against the window's 86% alone, why the fan's air is only 5% outdoor air in the first five minutes while the sash's top gap still lets moist air out at 0.39 times its rate alone, and why the door's undercut turns to carry the room's cold air into the hall from the eighth minute.
cases/ceilingVsFloorVent radiatorUnderWindow's room section with its radiator taken out, heated on a still 0 F night by 100 CFM of 117 F furnace air through a floor register under the window blowing straight up, or through a ceiling register near the inner wall blowing 45 degrees down towards the window, each a slot across the section, the floor, ceiling and inner wall layers of wood and gypsum that store heat, and a door undercut to the hall, from switch-on to 300 s. Backs a clip; the README says why the air at the ankles ends at 74 F with the floor register and 63 F with the ceiling vent, whose warm air stays under the ceiling and puts 46% of the heat into it while the cold air off the glass lies along the floor, and why slots across a 2-D section, jets that cling to the wall, the same supply temperature at both registers and no radiation bound what that can mean.
cases/crossVentilation windowAiring's room aired on a 0 C morning through its one 1.0 x 1.2 m window wide open or through two 0.5 x 1.2 m windows on opposite walls, the same 1.2 m2 of opening, in a 2.5 m/s breeze straight at the window wall put in as sourced wall pressures (+2.41 and -1.45 Pa) over 0-180 s, and on a still morning over 0-300 s, from the moment the windows open, the room's own air a passive scalar. Backs a clip; the README says why in the breeze the two windows replace 98% of the room's air in three minutes against 80%, a through-draught 16% above the orifice formula, why on a still morning the second window buys nothing (88% against 92% in five minutes, no air crossing the room), and why a steady wall pressure leaves the single window airing as in still air where real gusts would help it a little.
cases/ceilingVsUnderfloor underfloorVsRadiator's 3-D room on a still 0 C morning, started at a 16 C night setback and warmed with 1400 W (100 W/m2, EN 1264's floor limit) through the whole ceiling or the whole floor, with fvDOM radiation and every other wall a gypsum or wood layer that stores heat, from switch-on to 1200 s. Backs a clip; the README says why the heated ceiling, which gives 95% of its heat as radiation into the walls and floor, leaves the occupied zone's air at 18.2 C at the ankles after twenty minutes against 23.4 C over the heated floor, while its operative temperature reaches 20.1-20.8 C, and why massless heated surfaces, no thermostat and band-mean radiant temperatures make it a best case for the floor rather than a real screed's warm-up.
cases/fanHeaterVsOilRadiator ceilingVsUnderfloor's 3-D room at its 16 C setback on a still 0 C morning, with a 1500 W ceramic fan heater (built from a Lasko 754200's size, with a similar heater's 90 m3/h through it) or a seven-fin oil-filled radiator (built from a De'Longhi EW7707CM's) already hot at 95 C standing under the window, with fvDOM radiation, from switch-on to 300 s. Backs a clip; the README says why the radiator's 610 W against the fan heater's 1500 W is what this model's flat fins shed at 95 C and not the product's rating, why starting it hot is a constructed state rather than a warm-up, and why the two runs are on two meshes, the fan heater's checked against the other mesh only for its first 20 s.
cases/doorGapExcluder The gap under an inner door, the 10 mm undercut UK building rules ask for with a 3 mm head gap, between radiatorUnderWindow's room at 20 C and a cold hall at 10 C on a 0 C day, left open and blocked with a draught excluder, in a 2-D laminar section from rest to 240 s, the gaps meshed at 5, 10 and 20 cells across and a tracer on the hall's air. Backs a clip; the README says why the section's lack of side gaps makes the excluder seal better than on a real door, why its door as wide as the room makes the reach an upper limit, that the 3 mm head gap is ours and sets the flow, and that the blocked room's floor is cool too, from the leaf and the window.
cases/sofaLegsVsFlat A sofa's back 15 cm in front of radiatorCover's radiator held at 55 C, in a 5.5 m living room on a 0 C day with patio doors at the far end, an IKEA EKHOLMA standing on legs with 15 cm of open air under it or the same outline carried down to the floor, a 2-D section with fvDOM radiation and every wall and the sofa a layer that stores heat, from switch-on to 300 s. Backs a clip; the README says why the flat sofa's radiator gives 88.7% of the legged one's heat, nearly all the loss convection as it draws its air down behind the sofa instead of along the floor, and why a section with no sofa ends overstates how shut the flat slot is, so that the 11.3% is the section's and not a real sofa's.
cases/wetTowelRadiator A wet towel draped over radiatorCover's Stelrad K1 held at 55 C, against the same radiator bare, in a closed 2-D section of a small bedroom on a 0 C day with a window that mists, from switch-on to 600 s: humid air as a mixture of real gases in a solver variant with water vapour's own diffusivity, and the towel and the glass a coded function object that evaporates, condenses and pays the latent heat. Backs a clip; the README says why the towelled radiator's heat reaching the room is 38.9% of the bare one's over the first ten minutes (the rooms' air 19.3 against 27.9 C), why that share rises minute by minute and is not a settled one, why a towel spanning the sealed section's whole depth makes the room warm, and its air get humid and its window mist, about two and a half times as fast as a real room, and that the evaporation model is ours, with no measured drying on a radiator to check it against.
cases/radiatorCabinetTop A 3-column cast-iron steam radiator held at 215 F under the single-glazed sash of a pre-war New York living room, bare, in a sheet-steel cabinet with a perforated front and a solid top, and in the same cabinet with a perforated top, a 2-D section on a 0 C day with fvDOM radiation, the cabinet's sheet zero-thickness baffles, its holes strips of the same open share and every wall a layer that stores heat, from switch-on to 120 s. Backs a clip; the README says why the heat out of the cabinet is 60.7% of the bare radiator's with the solid top and 71.1% with the perforated one, counted like for like against bare's heat less what it put into the floor and wall where the cabinet stands, a count chosen after the result, why the holes also send more of it to the window, why the radiator stepping to 215 F at t = 0 makes the early burst and vortex in the solid room, and why a radiator as deep as the sealed section warms the room far faster than a real one, so that these are the first two minutes' shares and not settled ones.
cases/tallRoomFan A 3.3 m high Berlin Altbau room heated by radiatorCover's Stelrad K1, its panel held at 55 C and its fin-gap convector heating the air through the fitted conductance, under a tall box window, with no fan and with a small floor fan built from a Honeywell HT900E's retail figures blowing straight up at the ceiling, a 2-D section 5.0 x 3.3 m on a 0 C day with fvDOM radiation and every wall a layer that stores heat, from switch-on at 16 C to 300 s; a third run with the fan aimed at the radiator is kept. Backs a clip; the README says why the fan room is 3.3 K warmer at the ankles but 0.7 K cooler at 1.5 m and 1.7 K cooler under the ceiling at 300 s, its radiator giving 12.0% more heat, inside the 6.5-20% a real radiator gains with a fan, why the fan is a 2-D slot carrying the real fan's push per metre that mixes the room more evenly than a round fan would, why the section warms about four times as fast as the room it stands for, so that no time in it is a real time, and why the run with the fan aimed at the radiator is not used: its model radiator gains 33% with the fan, against about 20% for a real one.
cases/radiatorFanBar A Stelrad Compact K2 600 mm double panel at 55 C under a tall window in a 2-D study section 3.4 x 2.7 m on a 0 C day, bare and with a fan bar on its top grille blowing level into the room, with fvDOM radiation and walls that store heat, its fin-gap convector at a chosen gap that meets the catalogue rating, from switch-on at 16 C. Over the first two minutes the bar adds 2.2% to the radiator's heat and 26% less goes out through the window; the README says why the fin gap is chosen rather than sourced and why the 2-D section warms too fast.
cases/cyclistPaceLine Four identical road riders in single file at 40 km/h, 0.3 m apart, against the same rider alone, 3-D k-omega SST-SAS on cyclistBehindLorry's rider, 1.0-1.71 s means: the leader has 96.8% of the lone rider's 36.1 N and the riders behind 61.8, 52.5 and 56.6%; the README says why the 0.71 s window does not rank the riders behind.
cases/penguinFlight How fast an Adelie penguin would have to go to fly: a steady 3-D half model of the whole bird at a fixed 10 degrees nose-up makes its 47.1 N weight in lift at 64 m/s (230 km/h), the flippers carrying 72% of it, with two 2-D side sections from an impulsive start at its swimming and flying speeds; the README says why the sections' fall and hold are prescribed and their lift is not the bird's.
cases/acLouvreAngle A wall-mounted split air conditioner, built from a Mitsubishi MSZ-GS12NA-U1's published size, airflow and sensible cooling, switched on in a 30 C living room with its jet aimed 15 degrees up along the ceiling or 60 degrees down, a 3-D half room on the unit's centreline with the walls held at 30 C, from switch-on to 180 s. Both rooms cool alike, their means 0.13 K apart at 3:00, but the air at a seated person's ankles is 1.56 K colder with the vane down over the last minute and at the head only 0.13 K; the README says why humidity and condensation, half the makers' reason for aiming up, are left out, and why the cooling is a fixed sensible load.
cases/doorwayFanStove A wood stove giving a fixed 5 kW, a Charlton & Jenrick Go Eco 5's declared output, in one room of a two-room house, and a 20-inch box fan, a Lasko 3733 on low, in the doorway to the next room, in the top of the doorway blowing the warm air out or on the floor blowing the cold air in, a 3-D half house on the doorway's centreline with the walls held at each room's starting 24 and 14 C, from the fan coming on to 190 s. The high fan drives more air through the doorway and carries more heat into the next room, 1.87 against 1.41 kW, but stirs it against its cold walls, so over the last 30 s the air at a seated person's head there is 20.4 C with the fan high and 23.1 C with it low; the README says why walls that warm would narrow that gap, and why, with no radiation, the stove puts all its heat into the air.
cases/closedRegister A small one-storey US house with forced-air heating, warming from a 62 F night setback once the blower starts, with every floor register open or with the spare bedroom's register closed and its door shut, the whole house in 3-D, the registers fixed inlets carrying a hand duct calculation's flows and supply temperature from an American Standard furnace's blower line and LBNL-54005's leak sizes, from the blower's start to 300 s. The closed spare room stays at 62 F at head height while the open one reaches 74.9 F, and the rest of the house is 0.54 K warmer at 2:30 and 0.68 K at 5:00 with the register closed; the README says why the 70/30 split of the spare room's heat between the other rooms and the leaky ducts is the hand calculation's and not the solve's, why the house warms faster than a real one, and why nothing here speaks to the bill.
cases/airCurtain An air curtain over a shop's open front door on a still freezing day, off or on, a 2-D section through the middle of the door with the street at 0 C and the shop at 20 C, from the moment the door opens to 60 s, the curtain unheated at 6 m/s from a 6 cm slot aimed 20 degrees out and an outdoor-air tracer counting what gets in. The curtain keeps out 78% of the outdoor air that comes in without it at 30 s and 64% at 60 s, and the ankle air by the door holds at 54-61 F with it on against 32 F with it off; the README says why this is a typical curtain and not a code-compliant one (its jet reaches the floor at 1.0-1.3 m/s, not 2.0), why a shop as wide as its door floods far faster than a real one, and why nothing here speaks to the bill.
cases/weldingFumeExtraction Welding fume at a bench, an overhead canopy hood against an extractor drawing through a grille at the back of the bench, a 3-D workshop bay with a welder leaning over a 500 W arc whose fume is a passive tracer, from the strike at rest to 38-40 s. Under the hood 95% of the fume made rises past the welder's face by 38 s and at the bench none does, while both extractors clear 95-99% of the fume from the bay; the README says why the bench's near-zero at the face is a steady RANS plume and not an exposure, why the welder's lean decides much of the answer, and why the two runs stopped on different fume-negativity guards.
cases/cylinderRe3900_LES Re = 3900 circular cylinder LES, matched to Parnaudeau et al. (2008).
cases/finnedHeatSink A finned aluminium heat sink on a 15 W CPU in 2 m/s of 25 C air, the air and the sink solved together, the flow frozen at iteration 1500 and the heat solved on. The air carries out 15.003 W of the 15 W and the sink's resistance is 1.424 K/W; the README says why a hand estimate agrees within 2% only once it is told how much air goes through the fins, and why the resistance is the sink's and not the CPU's.
cases/teslaValve A Tesla valve of three loops in 2-D, water at 0.5 m/s driven through it the easy way and the blocking way under k-omega SST. The blocking way costs 1.57 times the pressure; the README says why it sends less water round the loops rather than more, and why at a transitional Reynolds number of 2500 the 1.57 is indicative.
cases/quadcopterDrag A bare quadcopter airframe with no rotors in 15 m/s of wind at 10 degrees nose-down, steady under k-omega SST with the drag split by part. The arms carry 44.7% of the 2.213 N; the README says why the total comes out 21.6% below a hand estimate of isolated parts, and why the drag on round tubes at these Reynolds numbers is the number most likely to be wrong.
cases/lightAircraftCruise A light aircraft built from NACA sections in cruise at 45 m/s, at 4 and 0 degrees, a half model under k-omega SST. Its lift carries 775 kg and its slope matches lifting-line theory within 5 to 9%; the README says why its drag reads a quarter high and its zero-lift angle 0.75 degrees off.
cases/acHeatingLouvre The same wall-mounted split unit as acLouvreAngle, now heating at the Mitsubishi MSZ-GS12NA-U1's rated 14,400 BTU/h and top airflow, switched on in a 15 C home office with its jet aimed 15 degrees up along the ceiling or 60 degrees down, a 3-D half room on the unit's centreline with heat-storing walls, floor and ceiling and a desk against the far wall, from switch-on to 180 s. Aimed down warms the floor and a seated person's feet, 2.83 K warmer over the last 90 s, but at the chest aimed up is 0.65 K warmer over that time, because the ceiling jet turns down the far wall onto the desk, until aimed down edges ahead in the last seconds; the README says why the warm-up is far faster than a real room's (a sealed room and a unit flat out with no thermostat), why the person is drawn and not modelled, and why the chest result rests on where the desk is.
cases/acSwingMode The same wall-mounted split unit as acLouvreAngle, cooling a 32 C bedroom closed up on a hot night, its vane held 10 degrees below horizontal or swinging 10-40 degrees down every 24 s through one corner outlet, a 3-D half room on the unit's and the bed's centreline with heat-storing walls, floor and ceiling and a queen bed against the far wall, from switch-on to 180 s. On swing the air at a sleeper's face is 1.12 K colder over the last 90 s and moves faster, 0.61 against 0.39 m/s, as the sweeping jet crosses the bed twice a cycle while the held jet runs under the ceiling, down the headboard wall and back along the bed; the README says why the cool-down is far faster than a real bedroom's (a sealed room and a unit flat out with no thermostat), why the sleeper is drawn and not modelled, where the swing's period and range come from, and why colder air at the face is not called better.
cases/summerStoreCurtain airCurtain's air curtain in summer: a convenience store's open glass door on a still day, the street at 35 C (95 F) and the store air-conditioned to 21.1 C (70 F), off or on, a 2-D section through the middle of the door from the moment it opens to 60 s, the same unheated unit at the same setting and an outdoor-air tracer counting what gets in. The curtain keeps out 69% of the outdoor air that comes in without it at both 30 s and 60 s, and the air at head height through the store is 75 F with it on against 90 F off at 60 s; the README says why a store as wide as its door heats far faster than a real one, why this is a typical curtain and not a code-compliant one (its jet reaches 15 cm above the floor at about 1.0-1.2 m/s, not 2.0), why the ankle air by the door is warmer with it on, and why dry air and one minute say nothing about the bill.
cases/ovenDoorOpen An electric oven the size of a GE JB645 30-inch range, just switched off after roasting a turkey at 325 F, its door dropped open or kept shut, in a sealed US kitchen at 20 C, a 3-D half kitchen on the range's centreline with heat-storing walls, floor and ceiling, the open oven's heat held in its steel liner and the shut range giving a fixed share of it, from switch-off to 300 s. With the door open the hot air leaves the top of the mouth and spreads under the ceiling, so the kitchen gains the oven's heat about twice as fast, 76 against 36 kJ in the half kitchen by 5:00, with 83% of the oven's heat still in it against 92%, and the air at standing head height ends at 24.6 against 22.8 C; the README says why the shut oven's release over an assumed hour is prescribed and not solved, why the open liner probably gives its heat too slowly and leaves out its radiation through the mouth, and why the open share rests on 13 kg of steel that is ours and not sourced.

What you should be able to do

Clone, run, and get a different answer if we got it wrong.

cd cases/roomFanInOut2D
./Allrun in        # or: ./Allrun out

Meshes and initial fields are generated by scripts in each case rather than committed, so a clean clone runs. Nothing under constant/polyMesh or in time directories is tracked — those are outputs.

What is not here

Results. No fields, no time directories, no renders. A case's job is to let you produce those yourself; a repository full of somebody else's output is not evidence, it is file size.

Reading a case

Every case README states what the case claims and, separately, what it cannot. The limits section is the part worth reading first — the modelling choices that would change the answer are listed there rather than left for you to find. If a case's results are used to make a claim publicly and the limits contradict that claim, the limits are correct and the claim is wrong.

Issues and corrections are welcome. A case that survives being checked is worth more than one that was never looked at.